| Customization: | Available |
|---|---|
| After-sales Service: | Support |
| Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
XINCHEN specializes in the production of R&D heating systems with a temperature control range of room temperature to 300ºC.
The heat exchange area is large, the temperature rise and failure are fast, and the heat transfer oil demand is small.
Only need to connect the equipment with the heat transfer oil inlet and outlet of the reactor device, from the top of the equipment liquid
Inlet add the heat transfer medium, turn on the add liquid button can easily remove the air in the system, set the temperature
requirements, the system can run automatically.
Widely used in chemical, pharmaceutical, or biotechnology reactors, control mixing tank temperature, metal(glass) double layer
reactor, thermal test platform, constant temperature control of material and equipment.
1. Circulating cooling medium: HTF, industrial alcohol or water-glycol mixture for circulating , conservation of resources.
2. Tight loop piping design, prevent cooling medium pollution, extending the cycle time of the use of cooling medium.
3. Multiple safety protection, more reliable.
4. Imported compressor, cold cascade refrigeration technology.
5. Using cold technology to ensure the stability of low temperatures.
6. It can be set to turn on the compressor and turn off the compressor temperature difference.
7. Ambient temperature detection function to prevent the system operating environment temperature is too high.
8. A variety of fault alarm( over-temperature alarm, sensor alarm, high pressure alarm, compressor overheating alarm, level alarm)
9. A fully enclosed design, low temperature process without water absorbtion, to ensure the purity of the cooling medium, to prevent ice crystals, prelong cooling medium life.
10. High-performance circulating pump, can ensure continuous operation 24 hours a day.
11. Using cold plate heat exchanger to provide heat transfer efficiency.
|
Model
|
DL-0250
|
DL-0400
|
DL-0700
|
DL-1000
|
DL-1450
|
DL-2000
|
DL-2600
|
|
|
Temp.Range
|
-25ºC~30ºC
|
|||||||
|
Temp control and display
|
ASET multi-function controller, optional color touch screen operation and display
|
|||||||
|
Temperature control selection
|
Control the temperature of cooling medium outlet
|
|||||||
|
Communication protocol
|
MODBUS RTU protocol RS485 interface
|
|||||||
|
Temperature feedback
|
The built-in cooling medium PT100 feedback
|
|||||||
|
Cooling
capacity
|
0ºC
|
1.5KW
|
2.4KW
|
4KW
|
7.5KW
|
10KW
|
15KW
|
20KW
|
|
-10ºC
|
1KW
|
1.5KW
|
2.7KW
|
6.3KW
|
8KW
|
12KW
|
15KW
|
|
|
-20ºC
|
0.55KW
|
0.8KW
|
1.5KW
|
3.5KW
|
5KW
|
7.3KW
|
10KW
|
|
|
Circulating pump flow rate / Pressure
|
Max 20L/min; 1.5bar
|
Max 20L/min; 1.5bar
|
Max 35L/min; 2.5bar
|
Max 35L/min; 2.5bar
|
Max 75L/min; 2.5bar
|
Max 75L/min; 2.5bar
|
Max 110L/min; 2.5bar
|
|
|
Storage tank volume
|
15L
|
15L
|
25L
|
25L
|
40L
|
60L
|
80L
|
|
|
Compressor
|
Copeland or Dorin
|
|||||||
|
Evaporator
|
Kaori Plate heat exchanger
|
|||||||
|
Operation panel
|
Touch button, LCD screen display
|
|||||||
|
Safety protection
|
Equipped with overload protection of refrigeration unit, high pressure switch, overload relay, thermel protection device, and other safety protection functions.
|
|||||||
|
Refrigerant
|
R404A
|
|||||||
|
Interface connector
|
DN15
|
DN20
|
DN20
|
DN20
|
DN20
|
DN20
|
DN25
|
|
|
Power supply
|
Single phase AC220V/50Hz
|
3 Phase AC380V/50HZ
|
||||||
|
Total power(Max)
|
1.5KW
|
2KW
|
2.5KW
|
3.5KW
|
5KW
|
6.5KW
|
8.5KW
|
|
|
Dimension
|
400*600* 1150mm
|
400*600* 1150mm
|
500*680* 1350mm
|
500*680*1350mm
|
680*700*1650mm
|
750*750*1800mm
|
850*850*1850mm
|
|
|
Shell material
|
Cold rolled plate spray (optional SUS304 shell)
|
|||||||
| Model | DL-5018 | DL-5040 | DL-5062 | DL-5090 | DL-50A1 | DL-50A2 |
| Temp range | -50~30C | |||||
| Temp feedback | PT100 | |||||
| Refrigeration output | 1.5KW@-10C 1.2KW@-20C 0.4KW@-40C |
3.2KW@-10C 2.7KW@-20C 0.8KW@-40C |
4.5KW@-10C 3.8KW@-20C 1.2KW@-40C |
6.2KW@-10C 5.5KW@-20C 1.5KW@-40C |
8.3KW@-10C 7KW@-20C 2.1KW@-40C |
12KW@-10C 10KW@-20C 3KW@-40C |
| Storage tank volume | 15L | 15L | 25L | 25L | 40L | 60L |
| Evaporator | Plate heat exchange | |||||
| Operation panel | LCD or Color touch screen | |||||
| Safety protections | Equipped with overload protection of refrigeration unit, high pressure switch, overload relay, thermal protection device and other safety protection functions | |||||
| Inlet/outlet size | DN15 | DN20 | DN20 | DN20 | DN20 | DN20 |
| Power supply | 1PH 220V/50HZ/3PH 380V/50HZ/3PH 220V/60HZ/400V/480V/600V | |||||
| Diemsnion | 40*60*125 | 40*60*125 | 50*68*145 | 50*68*145 | 65*70*165 | 65*70*165 |
| Model | DL-6518 | DL-6530 | DL-6562 | DL-6590 | DL-65A1 | DL-65A2 |
| Temp range | -65~-20C | |||||
| Temp feedback | PT-100 | |||||
| Refrigeration output | 1.5KW@-10C 1.2KW@-20C 0.4KW@-40C |
3.2KW@-10C 2.7KW@-20C 0.8KW@-40C |
4.5KW@-10C 3.8KW@-20C 1.2KW@-40C |
6.2KW@-10C 5.5KW@-20C 1.5KW@-40C |
8.3KW@-10C 7KW@-20C 2.1KW@-40C |
12KW@-10C 10KW@-20C 3KW@-40C |
| Storage tank volume | 15L | 15 | 25L | 25L | 40L | 60L |
| Compressor | TECUMSEH OR COPELAND | TECUMSEH OR COPELAND | TECUMSEH OR COPELAND | TECUMSEH OR COPELAND | TECUMSEH OR COPELAND | TECUMSEH OR COPELAND |
| Evaporator | Plate heat exchanger | |||||
| Operation panel | LCD or touch screen | |||||
| Safety protection | Equipped with overload protection of refrigeration unit, high pressure switch, overload relay, thermal protection device and other safety protection functions | |||||
| Inlet/outlet size | DN15 | DN20 | DN20 | DN20 | DN20 | DN20 |
| Power supply | 1PH 220V/50HZ/3PH 380V/50HZ/3PH 220V/60HZ/400V/480V/600V | |||||
| Diemsnion | 40*60*125 | 50*68*135 | 65*70*165 | 65*70*165 | 65*70*165 | 75*75*180 |
| Model | DL-8018 | DL-8030 | DL-8062 | DL-8090 | DL-80A1 | DL-80A2 |
| Temp range | -80~-20C | -80~-20C | -80~-20C | -80~-20C | -80~-20C | -80~-20C |
| Temp feedback | PT100 | PT100 | PT100 | PT100 | PT100 | PT100 |
| Refrigeration output | 0.6KW@-40C 0.4KW@-60C 0.2KW@-80C |
1.4KW@-40C 0.8KW@-60C 0.5KW@-80C |
2.8KW@-40C 1.6KW@-60C 0.9KW@-80C |
3.4KW@-40C 2.1KW@-60C 1.2KW@-80C |
4.8KW@-40C 4KW@-60C 2KW@-80C |
7.2KW@-40C 6KW@-60C 3KW@-80C |
| Storage tank volume | 15L | 15L | 25L | 25L | 40L | 60L |
| Compressor | TECUMSEH OR COPELAND | TECUMSEH OR COPELAND | TECUMSEH OR COPELAND | TECUMSEH OR COPELAND | TECUMSEH OR COPELAND | TECUMSEH OR COPELAND |
| Evaporator | Plate heat exchanger | |||||
| Operation panel | LCD or touch screen | |||||
| Safety protection | Equipped with overload protection of refrigeration unit, high pressure switch, overload relay, thermal protection device and other safety protection functions | |||||
| Inlet/outlet size | DN15 | DN20 | DN20 | DN20 | DN20 | DN20 |
| Power supply | 65 | |||||
| Diemsnion | 50*68*135 | 50*68*135 | 65*70*165 | 65*70*165 | 65*70*165 | 75*75*180 |
Refrigeration compressors : FRANCE TECUMSEH COMPRESSOR
Standard export wooden boxes (wooden cases) , with good protective materials inside and around the equipment , why we do this? For customer's side , they will feel happy if everything they had ordered from our factory which are in a good condition, for our side , the manufacturer, could get bulk orders from clients . In this way , both side could benefit from it.
Delivery terms: 10-25days of chillers, heaters only need to take 10-15days to finish them .