  • -45~30 Degrees Industrial Low Temperature Air Cooled Glycol Chiller
  • -45~30 Degrees Industrial Low Temperature Air Cooled Glycol Chiller
  • -45~30 Degrees Industrial Low Temperature Air Cooled Glycol Chiller
  • -45~30 Degrees Industrial Low Temperature Air Cooled Glycol Chiller
  • -45~30 Degrees Industrial Low Temperature Air Cooled Glycol Chiller
  • -45~30 Degrees Industrial Low Temperature Air Cooled Glycol Chiller
Find Similar Products
  • Overview
  • Product Parameters
  • Product Features
  • Detailed Photos
  • Packaging & Shipping
Overview

Basic Info.

Customized
Customized
Certification
CE
Structure
Desktop
Material
Steel
Type
Cooling Circulator
Temperature Range
-45c~Rt
Compressor
Copeland or Dorin Branded
Transport Package
Export Plywood Box
Specification
700*540*880mm
Trademark
XINCHEN
Origin
China
HS Code
8419899090
Production Capacity
1500sets/Month

Product Description

-45~30 Degrees Industrial Low Temperature Air Cooled Glycol Chiller
Refrigerated Circulators cooling temperature from -120ºC to 30ºC, widely used for various reactors, distillation or extraction system, laboratory, university research institute, automative, semiconductor and electrical test, chemical, pharmaceutical, petrochemical, biochemical and so on.

We have different models for your choice, with big cooling capacity, high cooling speed, which can greatly improve work efficiency and meet the actual needs of different users.
Product Parameters
Model
DL-5018
DL-5040
DL-5062
DL-5090
DL-50A1
DL-50A2
Temp.Range
-45ºC~RT
Temp control and display
ASET multi-function controller, optional color touch screen operation and display
Temperature control selection
Control the temperature of cooling medium outlet
Communication protocol
MODBUS RTU protocol RS485 interface
Temperature feedback
The built-in cooling medium PT100 feedback
 
Cooling 
capacity
-10ºC
1.5KW
3.2KW
4.5KW
6.2KW
8.3KW
12KW
-20ºC
1.2KW
2.7KW
3.8KW
5.5KW
7KW
10KW
-40ºC
0.4KW
0.8KW
1.2KW
1.5KW
2.1KW
3KW
Circulating pump flow rate / Pressure
Max 20L/min; 1.0bar
Max 20L/min; 1.5bar
Max 35L/min; 1.5bar
Max 35L/min; 1.5bar
Max 75L/min; 1.5bar
Max 75L/min; 1.5bar
Storage tank volume
15L
15L
25L
25L
40L
60L
Compressor
Copeland or Dorin
Evaporator
Plate heat exchanger
Operation panel
Touch button, LCD screen display
Safety protection
Equipped with overload protection of refrigeration unit, high pressure switch, overload relay, thermel protection device, and other safety protection functions.
Refrigerant
R404A
Interface connector
DN15
DN20
DN20
DN20
DN20
DN20
Power supply
Single phase AC220V/50Hz
3phase AC380V/50HZ
Total power(Max)
2.5KW
3KW
4KW
5.8KW
7KW
9KW
Dimension
400*600* 1250mm
400*600* 1250mm
500*680* 1450mm
500*680*1450mm
650*700*1650mm
750*750*1800mm
Shell material
Cold rolled plate spray (optional SUS304 shell)
 
Product Features

1. Circulating cooling medium: HTF, industrial alcohol or water-glycol mixture for circulating , conservation of resources.
2. Tight loop piping design, prevent cooling medium pollution, extending the cycle time of the use of cooling medium.
3. Multiple safety protection, more reliable.
4. Imported compressor, cold cascade refrigeration technology.
5. Using cold technology to ensure the stability of low temperatures.
6. It can be set to turn on the compressor and turn off the compressor temperature difference.
7. Ambient temperature detection function to prevent the system operating environment temperature is too high.
8. A variety of fault alarm( over-temperature alarm, sensor alarm, high pressure alarm, compressor overheating alarm, level alarm)
9. A fully enclosed design, low temperature process without water absorbtion, to ensure the purity of the cooling medium, to prevent ice crystals, prelong cooling medium life.
10. High-performance circulating pump, can ensure continuous operation 24 hours a day.
11. Using cold plate heat exchanger to provide heat transfer efficiency.

Detailed Photos

-45~30 Degrees Industrial Low Temperature Air Cooled Glycol Chiller

Packaging & Shipping

 

-45~30 Degrees Industrial Low Temperature Air Cooled Glycol Chiller
1. Packing method: Standard export wooden box or base on your requests.
2. Shipping method: By Express door to door, or by ship, based on your choice.
1) If delivery goods by Express, door to door service , generally about 5-7 working days reach.
2) If by air, deliver goods to your destination airport, about 5 working days reach.
3) If by sea, deliver goods to your local seaport, specific days and cost is based on different shipping line.

3. Warranty
Any broken or damages caused by delivery, will be afforded by Nanjing Ningkai company.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier