Use Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller Machine

Product Details
Customization: Available
After-sales Service: Support
Warranty: 1 Year
Still deciding? Get samples of US$ 10000/Set
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
25
Year of Establishment
2013-09-11
  • Use Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller Machine
  • Use Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller Machine
  • Use Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller Machine
  • Use Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller Machine
  • Use Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller Machine
  • Use Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller Machine
Find Similar Products
  • Overview
  • Product Parameters
  • Product Features
Overview

Basic Info.

Application
Industry, Lab
Customized
Customized
Certification
CE
Structure
Desktop
Material
Steel
Type
Cooling Circulator
Temperature Range
-65c~Rt
Compressor
Copeland or Dorin Branded
Transport Package
Export Plywood Box
Specification
700*540*880mm
Trademark
XINCHEN
Origin
China
HS Code
8419899090
Production Capacity
1500sets/Month

Product Description

Use Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller Machine

Refrigerated Circulators cooling temperature from -120ºC to 30ºC, widely used for various reactors, distillation or extraction system, laboratory, university research institute, automative, semiconductor and electrical test, chemical, pharmaceutical, petrochemical, biochemical and so on.

We have different models for your choice, with big cooling capacity, high cooling speed, which can greatly improve work efficiency and meet the actual needs of different users.
Product Parameters
Model
DL-6518
DL-6530
DL-6562
DL-6590
DL-65A1
DL-65A2
Temp.Range
-60ºC~RT
Temp control and display
ASET multi-function controller, optional color touch screen operation and display
Temperature control selection
Control the temperature of cooling medium outlet
Communication protocol
MODBUS RTU protocol RS485 interface
Temperature feedback
The built-in cooling medium PT100 feedback
 
Cooling 
capacity
-20ºC
0.85KW
1.5KW
2.5KW
3.4KW
4.8KW
7.2KW
-40ºC
0.7KW
1.2KW
2.1KW
2.8KW
4KW
6KW
-60ºC
0.4KW
0.6KW
1.2KW
1.6KW
2KW
3KW
Circulating pump flow rate / Pressure
Max 20L/min; 1.0bar
Max 20L/min; 1.0bar
Max 35L/min; 1.5bar
Max 35L/min; 1.5bar
Max 75L/min; 1.5bar
Max 75L/min; 1.5bar
Storage tank volume
15L
15L
25L
25L
40L
60L
Compressor
Copeland or Dorin
Evaporator
Kaori Plate heat exchanger
Operation panel
Touch button, LCD screen display
Safety protection
Equipped with overload protection of refrigeration unit, high pressure switch, overload relay, thermel protection device, and other safety protection functions.
Refrigerant
R404A/R23
Interface connector
DN15
DN20
DN20
DN20
DN20
DN20
Power supply
Single phase AC220V/50Hz
3Phase 380V/50Hz,could be customized
Total power(Max)
2.5KW
3KW
4KW
5.8KW
7KW
9KW
Dimension
400*600* 1250mm
500*680* 1350mm
650*700* 1650mm
650*700*1650mm
650*700*1650mm
750*750*1800mm
Shell material
Cold rolled plate spray (optional SUS304 shell)
 
Product Features

1. Circulating cooling medium: HTF, industrial alcohol or water-glycol mixture for circulating , conservation of resources.
2. Tight loop piping design, prevent cooling medium pollution, extending the cycle time of the use of cooling medium.
3. Multiple safety protection, more reliable.
4. Imported compressor, cold cascade refrigeration technology.
5. Using cold technology to ensure the stability of low temperatures.
6. It can be set to turn on the compressor and turn off the compressor temperature difference.
7. Ambient temperature detection function to prevent the system operating environment temperature is too high.
8. A variety of fault alarm( over-temperature alarm, sensor alarm, high pressure alarm, compressor overheating alarm, level alarm)
9. A fully enclosed design, low temperature process without water absorbtion, to ensure the purity of the cooling medium, to prevent ice crystals, prelong cooling medium life.
10. High-performance circulating pump, can ensure continuous operation 24 hours a day.
11. Using cold plate heat exchanger to provide heat transfer efficiency.

 

Use Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller MachineUse Plate Cool-Heat-Exchanger Low Temperature Chiller Condenser Chiller Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier