Overview

Basic Info.

Model NO.
DCW-4006N
Application
Industry, School, Hospital, Lab
Customized
Customized
Certification
CE, ISO
Structure
Desktop
Material
Stainless Steel
Type
Electric Thermostatic Water Bath
Temperature Range
-40~100c
Temperature Fluctuation Degree
0.1c
The Volume of Working Tank
260*200*140 (mm3)
Working Slot Size
180*140 (mm3)
Slot Depth
140 (mm)
Circulating Pump Flow
10 (L/Min)
Drain Valve
with
Transport Package
Standard Export Wooden Case
Specification
30*40*70mm
Trademark
XINCHEN
Origin
Nanjing China
HS Code
8419899090
Production Capacity
50/Month

Product Description

 

Hot Low Temperature Chiller

XINCHEN DC series cooling circulators are the true thermostatic control laboratory chiller.
 
This cooling circulator is ideal for applications such as cooling rotary evaporator, analytical instrumentation, laser etching, vacuum systems and jacketed reactors.
 
This equipment can also be used as a replacement to tap water cooling in laboratory applications.
 
They are compressor-based recirculating chillers that offer outstanding performance and high reliability as well as quiet operation and ease-of-use.
 
It can also be used as a heat source or cold source for a direct heating or cooling and auxiliary heating or cooling.
 
Powerful force/suction pump provides constant flow rate, while 2nd generation controller gives you the ideal solution when you need precise temperature control or cooling below ambient temperature.
Product Parameters
No
Model
Temp.Range       (ºC)
Temp Accurancy    (ºC)
Wroking Tank Size(mm)
Working Slot Size(mm)
Slot Depth(mm)
Pump Flow (L/min)
Drain Value
 
 
 
A01
SDC-6N
-5~100
±0.05ºC
250*200*150
180*140
150
6
With
DC-1006N
-10~100
±0.05ºC
250*200*150
180*140
150
6
With
DC-2006N
-20~100
±0.05ºC
250*200*150
180*140
150
6
With
DC-3006N
-30~100
±0.1ºC
250*200*150
180*140
150
6
With
DC-4006N
-40~100
±0.1ºC
250*200*130
180*140
130
6
With
 
 
 
A02
DC-0510N
-5~100
±0.05ºC
250*200*200
180*140
200
6
With
DC-1010N
-10~100
±0.05ºC
250*200*200
180*140
200
6
With
DC-2010N
-20~100
±0.05ºC
250*200*200
180*140
200
6
With
DC-3010N
-30~100
±0.1ºC
250*200*200
180*140
200
6
With
DC-4010N
-40~100
±0.1ºC
250*200*200
180*140
200
6
With
 
 
A03
DC-1015N
-10~100
±0.05ºC
280*250*200
235*160
220
15
With
DC-2015N
-20~100
±0.05ºC
300*250*200
235*160
200
15
With
DC-3015N
-30~100
±0.1ºC
300*250*200
235*160
200
15
With
DC-4015N
-40~100
±0.1ºC
300*250*200
235*160
200
15
With
 
 
A04
DC-0520N
-5~100
±0.05ºC
280*250*280
235*160
280
15
With
DC-1020N
-10~100
±0.05ºC
280*250*280
235*160
280
15
With
DC-2020N
-20~100
±0.1ºC
280*250*280
235*160
280
15
With
DC-3020N
-30~100
±0.1ºC
280*250*280
235*160
280
15
With
 
 
A05
DC-0530N
-5~100
±0.05ºC
440*325*200
310*280
200
15
With
DC-1030N
-10~100
±0.05ºC
440*325*200
310*280
200
15
With
DC-2030N
-20~100
±0.1ºC
440*325*200
310*280
200
15
With
DC-3030N
-30~100
±0.1ºC
440*325*200
310*280
200
15
With
 
A06
DCW-0506N
-5~100
±0.05ºC
260*200*140
180*140
140
6
With
DCW-2008N
-20~100
±0.05ºC
280*200*140
235*160
140
6
With
DCW-4006N
-40~100
±0.1ºC
260*200*140
180*140
140
6
With
Our Advantages

Hot Low Temperature Chiller
Hot Low Temperature Chiller

Product Features

1.Plug and play, no assembly required.
2.Using a big touch scree, easy to understand working conditions.

3.Air-cooled closed imported compressor refrigeration, cooling speed, low noise.
4.Upper and lower temperature alarm can be set. With over heat alarm system to ensure the safety apparatus.
5.Refrigeration system with overheat and overcurrent protective devices.
6.It have circulating pump, can be established second constant temperature field. Cold liquid can be cited outside the tank, cooling the experimental contain outside the bath.

7.The machine adopts microcomputer intelligent temperature control system with self-tuning intelligent PID automatic control function.
8.Intelligent computer can correct deviation of the temperature measurement, digital display resolution reaches 0.01~0.1ºC.
Hot Low Temperature ChillerHot Low Temperature ChillerHot Low Temperature ChillerHot Low Temperature ChillerHot Low Temperature Chiller

Packaging & Shipping

Hot Low Temperature Chiller1. Packing method: Standard export wooden box or base on your requests.
2. Shipping method: By Express door to door, or by ship, based on your choice.
1) If delivery goods by Express, door to door service , generally about 5-7 working days reach.
2) If by air, deliver goods to your destination airport, about 5 working days reach.
3) If by sea, deliver goods to your local seaport, specific days and cost is based on different shipping line.

3. Warranty
Any broken or damages caused by delivery, will be afforded by Nanjing Ningkai company.

Exhibition & Certification

Hot Low Temperature Chiller

About Us

Hot Low Temperature ChillerHot Low Temperature Chiller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier